The ecoTEC plus range of system boilers is available in a wide range of output models including 12kW, 15kW, 18kW, 24kW, 30kW and 37kW, meaning that there is a suitable model for almost any home. The stylish design and small dimensions also make it a perfect fit with any home.

Features and benefits:

  • Removable side panels – For additional accessibility flexibility
  • Highly efficient and economical to run – With up to an 89.4% efficiency rating (SAP 2009)
  • Advance modulation during periods of low heat demand – Ensuring low energy consumption and maximum efficiency
  • Flame lift detection system – Enabling more efficient and quieter combustion
  • Quiet Mark accredited – Thanks to being ultra quiet whilst in operation
  • Stylish contoured case design with drop down flap – Making this a boiler which fits with the décor of any home
  • Total system solution available from one manufacturer – Intelligent controls, cylinders and accessories all available
  • Dedicated models available for LPG – Giving a solution for off-gas areas
  • Step by step full text installation wizard - For quicker ‘first time right’ set up and installation

Download your ErP label here

ecoTEC plus 612 ErP label (63 kB)

ecoTEC plus 615 ErP label (62 kB)

ecoTEC plus 618 LPG ErP label (63 kB)

ecoTEC plus 618 ErP label (62 kB)

ecoTEC plus 630 ErP label (63 kB)

ecoTEC plus 630 LPG ErP label (63 kB)

ecoTEC plus 638 ErP label (63 kB)

Specifications

Specifications

Unit ecoTEC plus 612ecoTEC plus 615ecoTEC plus 618ecoTEC plus 624ecoTEC plus 630ecoTEC plus 637
ecoTEC plus

Gas inlet connection

mm

15

15

15

15

15

15

Connections heating flow and return

mm

22

22

22

22

22

22

Connector expansion relief valve (minimum)

mm

15

15

15

15

15

15

Flue size (concentric)

mm

60/100

60/100

60/100

60/100

60/100

60/100

Condensate drain (minimum internal diametre drain)

mm

19

19

19

19

19

19

Inlet gas working pressure (G20, natural gas)

mbar

20

20

20

20

20

20

Inlet gas working pressure (G31, propane)

mbar
  
37

37

37

37

"Gas flow rate at 15°C
and 1013 mbar (based on
hot water generation, if
applicable), G20"

m³/h

1.3

1.6

2

2.6

3.7

4.1
 

"Gas flow rate at 15 °C
and 1013 mbar (based on
hot water generation, if
applicable), G31"

kg/h
  
1.5

1.9

2.4

3

Approved flue type
 
"C13, C33,
C43, C53"

"C13, C33,
C43, C53"

"C13, C33,
C43, C53"

"C13, C33,
C43, C53"

"C13, C33,
C43, C53"

"C13, C33,
C43, C53"

NOx class
 
5

5

5

5

5

5

SEDBUK SAP seasonal efficiency 2009
%
89.0

89.0

89.3

89.4

89.4

89.2
ErP rating  AAAAAA
Boiler dimensions (WxHxD)mm440x720x338440x720x338440x720x338440x720x338440x720x372440x720x406
Weight (boiler only)kg363636373843
Nominal heat output
range of central heating at 50°C flow/30°C return"
kW3.3 - 12.93.3 - 16.14.2 - 19.3
9.4 - 32.1 (LPG) "
5.7 - 25.76.4 -32.2
5.5 - 19.3 (LPG)
7.1 - 39.6
 
Nominal heat output
range of central heating at 80°C flow/60°C return"
kW3.0 - 12.23.0 - 15.43.8 - 18.5
5.0 - 18.5 (LPG)
5.2 - 24.45.8 - 30.4
8.5 - 30.4(LPG)
6.4 - 37.6
Maximum DHW outputKw12.215.418.524.430.437.6
Maximum DHW inputKw12.415.718.9 24.93138.4
Maximum central heating inputkW12.415.518.624.730.938.1
Minimum central heating outputkW3.23.24
5.3 (LPG)
5.56.2
9.0 (LPG)
6.8
Maximum flow temperature°C858585858585
Adjustable flow temperature (default setting: 75°C)°C30 - 8030 - 8030 - 8030 - 8030 - 8030 - 80
Maximum CH system pressurebar333333
Mains water pressure required for maximum flow ratebar0.80.80.80.80.80.8
Expansion vessel capacitylitre101010101010
Volume of water circulating (ΔT= 20 K)l/h5256627961,0491,3071,617
Approx. Condensation volume at 50°C feed/30°C returnl/h1.21.61.92.53.13.8
Remaining feed head of
pump (at nominal circulation
water volume)
bar0.250.250.250.250.250.25

Electrical supply voltage

V-/ Hz

230/50

230/50

230/50

230/50

230/50

230/50

Internal fuse (slow) main voltage

A

2

2

2

2

2

2

Minimum electrical power consumption

W

35

35

35

35
4555
Maximum electrical power
consumption
W5055657080115
Standby electrical power consumptionW< 2 < 2 < 2 < 2 < 2 < 2
Protection class IP X 4DIP X 4DIP X 4DIP X 4DIP X 4DIP X 4D
CE certificate registration number CE‑
0085CM0320"
CE‑
0085CM0320"
CE‑
0085CM0320"
CE‑
0085CM0320"
CE‑
0085CM0320"
CE‑
0085CM0320"

Related Products

Related Products

vSMART app control

Heating and hot water control at your fingertips

  • Smart phone app for both Android and Apple iOS Application
  • Self learning
  • Weather compensation
  • Connect multiple vSMART controllers to one app
  • Wireless connection

Downloads

Alternative products

Alternative products

VRC 470f

Wireless weather compensating programmable room thermostat

  • Classed as enhanced load compensator adding 3% to the SEDBUK efficiency rating
  • Automatic summer/winter time change over
  • Includes a service reminder function
  • Cylinder boost function
  • Holiday function

auroTHERM Exclusive Vacuum Tube Collectors

High efficiency solar thermal evacuated tube collectors

  • Standardised roof bracket system
  • Vertical collector available for on-roof and flat roof installations with mounting bracket options
  • Tubes guaranteed for 10 years against loss of vacuum
  • Up to six collectors can be connected in a series
  • Compound Parabolic Concentrator (CPC)