Vaillant Logo

Fast access

  • Go to content
  • Go to navigation
  • Go to search

Choose your language

  • Would you like to go to our Homeowners section?
  • United Kingdom
Please choose your country
  • Home
  • Sitemap

Change your fontsize

  • ABC
  • ABC
  • ABC

  • Products
    • Domestic boilers
    • Storage cylinders
    • Controls
    • Solar
    • Heat pumps
    • Commercial boilers
    • Mechanical ventilation heat recovery
  • Literature
  • Training
    • Training centres
    • Courses
    • Booking a course
    • Customer testimonials
  • After sales service
    • Warranty registration
    • FAQs
    • Glossary
    • Vaillant Advance
  • Contact us
    • Find local Vaillant contact
  • Partner Login

Products

  •  
  • Domestic boilers
  • Storage cylinders
  • Controls
  • Solar
  • Heat pumps
    • Ground Source Heat Pumps
      • geoTHERM
      • geoTHERM exclusive
      • Frequently asked questions
      • Heat pump installation diary
      • Ground source heat pump calculator
    • Air to Water Heat Pumps
    • Air to Air Heat Pumps
    • Calculators
  • Commercial boilers
  • Mechanical ventilation heat recovery
 
  • Trade
  • Products
  • Heat pumps
  • Ground Source Heat Pumps
  • geoTHERM exclusive
Zoom Image

geoTHERM exclusive

geoTHERM exclusive offers a complete solution to your home comfort providing heat in the winter, cooling in the summer and domestic hot water throughout the year, all from a single unit.
geoTHERM exclusive is equipped with the weather-compensated energy-balance control unit incorporating an additional passive cooling function, 175 litre stainless steel domestic hot water (d.h.w.) cylinder and a 4 kW electric auxiliary (backup) heater. During the summer months, excess thermal energy from the building can be removed and transferred to the ground via a heat exchanger, cooling the building when used with a specifically designed underfloor heating system.
geoTHERM exclusive includes an integrated passive cooling function when used with an underfloor heating system. During the summer months the heat recovery process can be reversed. The excess heat in the living space is withdrawn via the underfloor heating system and then transferred to the ground. So, instead of withdrawing thermal energy from the ground, as in the case with heating operation, the heat is withdrawn from the living space and transferred to the ground via the ground loop collector.

Features and benefits

Free use of environmental energy for heating Reduced overall CO2 emissions, no CO2 emissions on site. "Every kW used to run the heat pump generates over 4 KW heating energy
(BOW35 ΔT 5K: EN 14511)"
Refrigerant R 407C Non-hazard refrigerant with zero ozone depletion potential
Sensor-controlled refrigerant circuit Full monitoring of the refrigerant circuit via control without spacial measurement instruments
High efficiency evaporator with an injection system Increasing the energy transfer from the ground to the heating system
A flow temperature of up to 62°C, and includes a built-in electric auxiliary heating, adjustable to 2 and 4 kW Only one appliance needed for heating, no additional heating appliances required
Integrated heat source and heating circuit pump with a 3 way diverter valve for domestic hot water production Everything in one appliance, fast and clean installation
Variable connection of the heat source and heating system, all in a compact structure Extremely short mounting period with added location flexibility
Multi-stage sound insulation (MSI) with sound insulated framing module, vibration absorbing base plate and flexible connection pipe work "Whisper" silent running making installation in living area possible, if required
Weather-compensated energy-balance control unit Energy efficient heating giving clean and efficient use of free energy
Large back-lit display with full diagnostic overview, including an environmental energy yield display mode Easy fault finding and viewable energy measurements to give an energy saving overview
vrnetDIALOG for remote optimisation and intelligent servie support Remote monitoring of the heat pump parameters allwing an optimisation of the heat pump set up
Integrated 175l stainless steel cylinder and ability for passive cooling One appliance for everything: Full heating and cooling comfort
SplitMounting concept to seperate the heat pump in weight and volume Easy transport to duifficult locations an easier handling for installers
Durable heat pump scroll compressor with a 10 year warranty and 3 years warranty on parts and labour (includes a commissioning visit) Peace of mind

Downloads

  • ground-source-heat-pump-brochurepdf (1.86 MB)
  • geotherm-exclusive-operating-manualpdf (0.00 MB)
  • geotherm-exclusive-installation-manualpdf (6.48 MB)
  • cooling-supplement-to-the-installation-manualpdf (3.71 MB)
  • geotherm-exclusive-transport-manualpdf (0.18 MB)
  • geotherm-exclusive-assembly-manualpdf (0.89 MB)

Product Quick Search


  • Recommend Site
  • Print
  • PDF
Top
  • © 2012 Vaillant
  • Conditions for use
  • Data protection
  • Legal disclaimer
  • Registered office
  • News
  • Facebook
  •   
  • Twitter Twitter